Optimasi Faktor Eksposi Pemeriksaan Radiologi Thorax melalui Pengukuran Entrance Surface Dose (ESD) dengan Phantom pada Kondisi Kegawatdaruratan

Authors

  • Fisnandya Meita Astari Universitas ‘Aisyiyah Yogyakarta Author
  • Ayu Mahanani Universitas ‘Aisyiyah Yogyakarta Author
  • Winona Fajar Antika Universitas ‘Aisyiyah Yogyakarta Author

DOI:

https://doi.org/10.62710/y7jhnz44

Keywords:

Thorax; Emergency; Exposure; Entrance Surface Dose;

Abstract

Background: Emergency thorax radiography in the ER/ICU using mobile X-rays often faces space constraints and challenging patient positioning, risking higher radiation exposure. Objective: This study aims to determine the Entrance Surface Dose (ESD) values in thorax radiography and identify the optimal combination of exposure factor parameters to minimize ESD. Methods: This quantitative experimental study was conducted at the Radiology Laboratory of Universitas 'Aisyiyah Yogyakarta in February 2026 using an Anthropomorphic Thorax Phantom and a BMX-AR 30 mobile X-ray unit. Variations included FFD (100, 120, 150, 180 cm) and several exposure factors. ESD values were measured using a Raysafe X2 multimeter. Results: Increasing FFD consistently reduced ESD values. While FFD 180 cm yielded the lowest dose, it is impractical in critical care. As a pragmatic middle ground, FFD 120 cm is the most realistic clinical choice. By implementing a high kV-low mAs technique, the combination of 86 kV and 4 mAs at FFD 120 cm proved to be the best parameter, minimizing the ESD value to 0.3 mGy. Conclusion: This study successfully mapped ESD values and identified the optimal exposure combination (86 kV, 4 mAs, FFD 120 cm) to minimize radiation doses safely below the national DRL limit.

Downloads

Download data is not yet available.

References

Badan Pengawas Tenaga Nuklir. (2024). Panduan Teknis Penetapan dan Pemanfaatan Diagnostic Reference Level (DRL) Nasional untuk Optimasi Proteksi Radiasi Pasien.

Bamgboye, E. A., Schandorf, A., & Inkoom, S. (2019). Assessment of Patient Entrance Surface Dose and Image Quality in Chest Radiography in Selected Hospitals in Nigeria. Journal of Radiation Research and Applied Sciences, 12(1), 215–222.

BAPETEN. (2024). Penetapan Nilai Diagnostic Reference Level (DRL) Nasional untuk Pemeriksaan Radiologi Diagnostik dan Intervensional.

Brady, A. P., Allen, B., Chong, J., Kotter, E., Kottler, N., Mongan, J., Oakden-Rayner, L., dos Santos, D. P., Tang, A., Wald, C., & Slavotinek, J. (2024). Developing, purchasing, implementing and monitoring AI tools in radiology: practical considerations. A multi-society statement from the ACR, CAR, ESR, RANZCR & RSNA. Insights into Imaging, 15(1). https://doi.org/10.1186/s13244-023-01541-3

Brody, A. S., & Zeman, R. K. (2020). Principles of Emergency Radiology and Emergency Imaging. In Emergency Radiology: Principles and Practice (pp. 15–32).

Esien-Umo, E. O., Inyang, S. O., & Obed, R. I. (2022). Radiation Dose Reduction and Image Quality Optimization in Mobile Digital Chest Radiography Using High kVp Technique. West African Journal of Radiology, 29(2), 114–121.

European Commission. (2018). European Guidelines on Diagnostic Reference Levels for Medical Exposures (Radiation Protection No. 185).

Grainger, R. G., Allison, D. J., Adam, A., Dixon, A. K., Gillard, J. H., & Schaefer-Prokop, C. M. (Eds.). (2015). Grainger & Allison’s Diagnostic Radiology: A Textbook of Medical Imaging (6th ed.). Churchill Livingstone/Elsevier.

Hidayati, S., Syaifudhini, M., & Masrochah, S. (2017). Analisis Entrance Surface Dose (ESD) pada Pemeriksaan Thorax Proyeksi Anteroposterior Menggunakan Mobile X-Ray. Jurnal Imejing Diagnostik (JID), 3(2), 188–194.

Hiqa. (2023). Diagnostic Reference Levels Health Information and Quality Authority Diagnostic Reference Levels Guidance on the establishment, use and review of diagnostic reference levels for medical exposure to ionising radiation.

ICRP. (2017). Diagnostic Reference Levels in Medical Imaging. Annals of the ICRP, 46(1), 1–144.

ICRP. (2021). Radiation Protection in Digital Radiology. Annals of the ICRP, 50(2), 1–120.

Lampignano, J. P., & Kendrick, L. E. (2018). Bontrager’s Textbook of Radiographic Positioning and Related Anatomy (9th ed.). Elsevier Health Sciences.

Ramantisan, S., Suliman, I. I., & Abushab, K. M. (2022). Evaluation of the Effect of High-kVp Technique on Entrance Surface Dose and Image Quality in Digital Chest Radiography. Journal of Medical Physics and Imaging Science, 8(1), 45–53.

Ratio, R., Wijaya, A., & Saputra, H. (2024). Studi Komparatif Kualitas Citra dan Dosis Radiasi Permukaan pada Radiografi Thorax Proyeksi AP dan PA Menggunakan Digital Radiography. Jurnal Radiografer Indonesia, 7(1), 12–19.

Risalatul, L., Milvita, D., & Prasetio, H. (2020). Penentuan Nilai Entrance Surface Dose (ESD) pada Pemeriksaan Radiografi Dada Dewasa Menggunakan Computed Radiography. Jurnal Fisika Unand, 9(2), 241–247.

Risalatul Latifah , Muhammad Rosyid, Firdy Yuana, A. H. (2020). Journal of Vocational Health Studies DOSE PROFILE FOR PATIENTS UNDERGOING RADIOGRAPHY. 04, 72–77. https://doi.org/10.20473/jvhs.V4.I2.2020.72-77

Rusli, M., Mulyana, I., & Husna, S. N. (2024). Optimisasi Faktor Eksposi dan Kualitas Citra terhadap Dosis Radiasi (Entrance Surface Dose) Pemeriksaan Thorax Menggunakan Mobile X-Ray. Jurnal Imejing Diagnostik (JID), 10(1), 45–52.

Sabankouy, B., Touré, A., Diallo, M., & Sidibé, S. (2024). Assessment of Entrance Surface Dose (ESD) and Image Quality in Portable Chest Radiography Within Emergency and Intensive Care Units. International Journal of Radiation Research, 22(2), 341–348.

Sarankouy, B. (2024). Optimization of Radiation Protection for Emergency Mobile Chest Radiography Using High kVp and Low mAs Parameters. International Journal of Medical Imaging, 12(1), 18–25.

Tjuanda, R. (2021). Evaluasi Kualitas Citra Radiografi Thorax Portabel pada Variasi Focus to Film Distance (FFD) di Ruang Rawat Intensif. Jurnal Radiologi Indonesia, 6(3), 142–148.

Vassileva, J., Al-Dhuhli, H., Al-Naemi, H., Al-Suwaidi, J., Chiksov, V., El-Nachef, L., Jauhari, A., Kharita, M. H., & Rehani, M. M. (2019). IAEA Survey of Diagnostic Reference Levels for Adult Radiographs in Several Countries: Initial Results and Regional Patterns. Radiation Protection Dosimetry, 184(3–4), 412–416.

Wardani, R. K., & Pratama, S. (2025). Dose Reduction and Image Quality Optimization in Mobile Digital Thorax Radiography Using Low-Exposure Factors. International Journal of Health and Clinical Imaging, 4(1), 12–20.

World Health Organization. (2020). Communicating Radiation Risks in Paediatric Imaging: Information to Support Healthcare Discussions.

Published

2026-06-22 — Updated on 2026-06-22

Versions

How to Cite

Astari, F. M. ., Mahanani, A. ., & Antika, W. F. . (2026). Optimasi Faktor Eksposi Pemeriksaan Radiologi Thorax melalui Pengukuran Entrance Surface Dose (ESD) dengan Phantom pada Kondisi Kegawatdaruratan. Jurnal Ragam Pengabdian, 3(2), 2485-2497. https://doi.org/10.62710/y7jhnz44