Abstract

This study evaluates the reliability of the 20 kV distribution network at PT PLN (Persero) UP3 Surakarta, focusing on the JJR-03 feeder. Using the Section Technique method, the network was divided into sections to calculate failure rates, disruption duration, and reliability indices (SAIFI and SAIDI) based on disruption data, customer numbers, line length, and network components. The results show that the JJR-03 feeder has a SAIFI of 5.538 times/year and a SAIDI of 20.930 hours/year, with Section 1 contributing the largest disruptions due to its longer line length, more components, and higher customer density. ETAP 19.0.1 simulations revealed initial SAIFI and SAIDI values of 7.766 times/year and 21.341 hours/year. After optimizing recloser placement in the highest-disturbance section, SAIFI decreased to 5.821 times/year and SAIDI to 16.164 hours/year. These findings indicate that strategic recloser placement can significantly improve distribution system efficiency by reducing outage frequency and duration. The study provides a basis for developing more effective protection system strategies to enhance the reliability of the 20 kV distribution network on the JJR-03 feeder.

Downloads

Download data is not yet available.

References

Aprialdi, R., & Aini, Z. (2023). Analysis of the reliability of electrical distribution systems using the technique section method and rnea fedder gibp-mesir. 07(02), 133–145. https://doi.org/https://doi.org/10.21831/jee.v7i2.63118

Arman, Joko, T. R., & Harimurti, R. (2024). Analisis Penempatan Recloser Terhadap Keandalan Sistem Tenaga Listrik Jaringan Distribusi 20kV di PT.PLN (Persero) ULP AMUNTAI. https://doi.org/https://doi.org/10.26740/jte.v13n2.p130-134

Fahrurrozi, A., Anshar, C. N., & Ridal, Y. (2024). Analisa Keandalan Sistem Distribusi 20 kV Dengan Metode Section Technique Di PT . PLN ( Persero ) ULP Muara Labuh Solok Selatan Sumatera Barat. 5(2). https://doi.org/https://doi.org/10.53695/jm.v5i2.1122

Gozali, R. B. M., Prasetyono, S., & Mufaizah, R. (2022). Analisis Perbandingan Keandalan Sistem JaringanDistribusi Berkonfigurasi Radial Dan Loop Menggunakan Metode Section Technique. 3, 12–26. https://doi.org/https://doi.org/10.31328/jasee.v3i02.113

Luthfiyani, U. K., Setiawan, A., & Arifin, S. (2023). Analisis Perbandingan Indeks Keandalan Sistem Jaringan Distribusi dengan Metode Section Technique dan Reliability Index Assessment ( RIA ): Studi Kasus Gardu Induk Balaraja. 2(1), 250–264. https://doi.org/10.55123/insologi.v2i1.1782

Manoppo, F. R., Ir. Hans Tumaliang, M., & Sartje Silimang, ST, M. (2023). Evaluasi Keandalan Sistem Distribusi Menggunakan Metode Section Technique Pada PT . PLN ( Persero ) Area Kotamobagu. 1–10. https://repo.unsrat.ac.id/3415/1/JURNAL FAHMI RIZKY MANOPPO %2816021103044%29.pdf

Mardiansyah, M. S. (2026). Evaluasi keandalan sistem distribusi menggunakan indeks saidi, saifi, dan caidi pada pt. pln (persero) ulp grogol tahun 2024. 63–74. https://doi.org/https://doi.org/10.26740/jte.v15n1.p63-73

Oktavia, Y., Gusti, K., Studi, P., Elektro, T., Teknik, F., & Surakarta, U. M. (2021). Analisa Keandalan Sistem Distribusi Menggunakan Metode Section Technique Di PT PLN ULP3 Salatiga. https://eprints.ums.ac.id/97851/1/Naskah Publikasi_Yeni Oktavia_D400170072.pdf

Pangestu, A. B., Putri, R. D. M., Hudallah, N., & Andrasto, T. (2023). ANALISIS KEANDALAN SISTEM DISTRIBUSI JARINGAN SUTM DI PT . 14(1), 107–126. https://doi.org/https://doi.org/10.24176/simet.v14i1.9109

Pratama, M. A., Setiyono, Y. W., Rahman, A. H., Teknik, D., & Mada, U. G. (2024). Optimisasi Penempatan Recloser dan Sectionalizer untuk Memperbaiki Keandalan Jaringan pada Penyulang WNI10 Menggunakan Simulasi Reliability Assessment. 5(2), 56–64. https://doi.org/https://doi.org/10.22146/juliet.v5i2.86532

Setiawan, A. F., & Suheta, T. (2020). Analisa Studi Keandalan Sistem Distribusi 20 KV di PT . PLN ( PERSERO ) UPJ Mojokerto Menggunakan Metode FMEA ( FAILURE MODE EFFECT ANALYSIS ). 3. https://doi.org/https://doi.org/10.30651/cl.v3i1.4304

Sihombing, G. (2022). Analisis Indeks Keandalan Secara Teknis dan Ekonomis Jaringan Distribusi 20 KV Menggunakan Metode Section Technique pada PT. PLN (Persero) Rayon Belawan. 06(02), 105–115. https://doi.org/https://doi.org/10.21831/jee.v6i2.53946

Sofyan, S., Achmad, A., & P, I. A. S. (2022). Studi Perbaikan Keandalan Sistem Jaringan Distribusi Melalui Penambahan Recloser Pada Penyulang Pajalau PT . PLN ( Persero ) Menggunakan Metode Section Technique. 19(2), 106–115. https://doi.org/https://doi.org/10.31963/elekterika.v6i2.3688

Suparta, M. M., & Irawan, M. I. (2025). Optimisasi Penempatan Recloser Dengan Metode AHP-Vikor Untuk Mengurangi Wilayah Padam dan Meningkatkan Keandalan Distribusi Listrik. 10(9), 7608–7624. https://doi.org/https://doi.org/10.36418/syntax-literate.v10i9.61407

Ummara, A., & Suprawikno. (2025). Optimasi Penempatan Recloser Jaringan Distribusi Menggunakan Metode Section Technique Dan Algoritma Grey Wolf Optimizer. 8(2), 274–282. https://doi.org/https://doi.org/10.36595/jire.v8i2.1703

Widagdo, R. S., Budiono, G., Slamet, P., Sultan, M., & Habibullah, A. (2024). Analysis of The Reliability Index of The Platuk Feeder Distribution System at PT . PLN ULP Kenjeran with Section Technique Method. 6(2). http://jurnalnasional.ump.ac.id/index.php/JRRE

Published

2026-06-26

How to Cite

Ridwan , A. A., & Fadlilah, U. . (2026). Analisis Keandalan Jaringan Distribusi 20 kV di UP3 Surakarta Menggunakan Metode Section Technique Berbasis Optimal Placement Recloser. Jurnal Ragam Pengabdian, 3(2), 2884-2898. https://doi.org/10.62710/93yeqh04